hacklink al hack forum organik hit kayseri escort deneme bonusu veren siteler deneme bonusu veren siteler canlı casino siteleri grandpashabet bahis siteleri deneme bonusu veren sitelercasibomcasibom girişBetandreas APKfixbetgrandpashabetbets10casibomonwincasibomjojobet güncel girişSakarya escortSakarya escortiptvselçuksportsgrandpashabetultrabetbahis siteleri토토사이트Sekabetcasibom girişcasibomcasibomdeneme bonusu veren sitelerimajbetcasibomSekabetBetgarantibets10casibom girişholiganbetcasibom günceldeneme bonusucasibomcasibombettiltkingroyalGanobetonwincasibommariobetKingroyalCasibompubg mobile uc satın alimajbet girişjojobetsahabetcasibomcasibom güncel girişcasibom 887 com giriscasibom girişbahiscasino girişcasibomcasibomcasibom 887sahabetbetwooncasibom twittersekabetdinamobet twitterbetzulabetkanyonmarsbahismarsbahismarsbahisgoldenbahisjokerbetmilanobetpashagamingrestbetbetvoleRoyalbetGalabetkingbettingポルノ映画 moviejojobet güncel girişbetcio güncel girişbetciomatbetjojobettez yazdırmaGanobetcasibomonline casino ve bahis
-28%

Fluke 106 Palm-sized Digital Multimeter

Fluke 106 Digital Multimeter – Palm-sized

The Fluke 106 digital multimeter has a 2.4-inch color display and fits the palm of your hand so you can take it anywhere. It is so cute, with up to four units displayed at once, that you will find yourself having fun using it.

For additional information, you can also visit our YouTube Channel.
Click Here to view our entire product range.

 

  for Bulk Quantity / Product Specification Sheet.

Get Quote

Description

Fluke 106 Palm-sized Digital Multimeter

The Fluke 106 is a palm-sized digital multimeter that provides essential electrical measurements. It’s compact, lightweight, and easy to use in the workplace. This multimeter has all of the features you need for basic electrical work: True RMS AC/DC voltage measurement, full set of electrical measuring functions (resistance, continuity, capacitance), a max hold function that freezes the meter reading on the display and battery life indicator. You can measure larger current draws using the higher range current clamp. A simple press of a button allows you to make measurements in dark places without turning on additional lights.

  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Data hold

 

Specifications: Fluke 106 Palm-sized Digital Multimeter

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Accuracy Specifications
Function Range Resolution Accuracy
AC Volts
(40 Hz to 500Hz)1
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3
Diode Test2 2.000 V 0.001 V 10 %
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance3 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency4 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA
Duty Cycle4 1 % to 99 % 0.1 % NA
AC Current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
  3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC Volts 600 V 1 >10 MΩ <100 pF 2 >60 dB at dc,
50 Hz or 60 Hz
\AC Millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz
DC Volts 600 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
  1. 6 x 105 V Hz Max
  2. For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground 600 V
Display (LCD) 6000 counts, updates 3/sec
Battery Type 2 AAA, NEDA 24A, IEC LR03
Battery Life 200 hours minimum
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative Humidity
Operating Humidity Non-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs 11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL) 142 mm x 69 mm x 28mm
Weight 200 g
IP Rating IEC 60529: IP 40
Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment IEC 61326-1: Portable
Electromagnetic Compatibility Applies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1
  1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.
has been added to your cart:
Checkout
Enquire Now
Call Us